Twin Jack Roped


                             
    Single Opening (F)               Double Opening (F/R)

= Platform Width
= Platform Depth
= Hoistway Width
= Hoistway Depth
= Clear Door Width
= Clear Door Height
= Overhead
= Pit Depth
= Door Clearance
= 5″ for Regular Type Doors
= 6 3/4” for Pass Type Doors
Download Available Information
Click on Image or Title below
 
Microsoft Word File PDF File Specifications
Printable Brochures
 icon_pdf Quote Request Forms

Notes:

  • Overhead dimensions are based on 6 foot high car gate.
  • Two section car gates are not recommended for high usage installations or wide openings.
  • For extra high door openings requirements, or special conditions, consult your representative.

Standard Cab Height H = 8′ -0″
Minimum Overhead for Single Section Gates:
= 14′ -6″
Minimum Overhead for Two Section Gates:
= 12′ -4″

Freight Elevators – Standard Specifications
 Cap.  Platform
Platform Width x Platform Depth
Hoistway
With
Power
Regular
Doors
Hoistway Width x Hoistway Depth
Hoistway
With
Power
Pass
Doors
Hoistway Width x Hoistway Depth
Pit
Depth
Pit Depth
Front
(F)
Rear

(R)
Clear
Inside
With
Single
Section
Clear
Inside
With
Two
Section
Door
Width
And
Height
Clear Door Width x Clear Door Height
Elevation
& Plan
View
Drawings
 4000 7′ -0″ x
8′ -0″
9′ -0″ x
8′ -8″
9′ -0″ x
8′ -9 3/4
4′ -6″ F 6′ -8″ x
7′ -7″
6′ -8″ x
7′ -4 1/2
6′ -8″ x
8′ -0″
DWG File PDF File
 4000 7′ -0″ x
8′ -0″
9′ -0″ x
8′ -10″
9′ -0″ x
9′ -1 1/2
4′ -6″ F/R 6′ -8″ x
7′ -6″
6′ -8″ x
7′ -1″
6′ -8″ x
8′ -0″
DWG File PDF File
 5000 8′ -0″ x
9′ -0″
10′ -2″ x
9′ -8″
10′ -2″ x
9′ -9 3/4
4′ -6″ F 7′ -8″ x
8′ -7″
7′ -8″ x
8′ -4 1/2
7′ -8″ x
8′ -0″
DWG File PDF File
 5000 8′ -0″ x
9′ -0″
10′ -2″ x
9′ -10″
10′ -2″ x
10′ -1 1/2
4′ -6″ F/R 7′ -8″ x
8′ -6″
7′ -8″ x
8′ -1″
7′ -8″ x
8′ -0″
DWG File PDF File
 6000 10′ -4″ x
10′ -0″
12′ -6″ x
10′ -8″
12′ -6″ x
10′ -9 3/4
4′ -6″ F 10′ -0″ x
9′ -7″
10′ -0″ x
9′ -4 1/2
10′ -0″ x
8′ -0″
DWG File PDF File
 6000 10′ -4″ x
10′ -0″
12′ -6″ x
10′ -10″
12′ -6″ x
11′ -1 1/2
4′ -6″ F/R 10′ -0″ x
9′ -6″
10′ -0″ x
9′ -1″
10′ -0″ x
8′ -0″
DWG File PDF File
 8000 10′ -4″ x
12′ -0″
12′ -10″ x
12′ -8″
12′ -10″ x
12′ -9 3/4
4′ -6″ F 10′ -0″ x
11′ -7″
10′ -0″ x
11′ -4 1/2
10′ -0″ x
8′ -0″
DWG File PDF File
 8000 10′ -4″ x
12′ -0″
12′ -10″ x
12′ -10″
12′ -10″ x
13′ -1 1/2
4′ -6″ F/R 10′ -0″ x
11′ -6″
10′ -0″ x
11′ -1″
10′ -0″ x
8′ -0″
DWG File PDF File
 10000 10′ -4″ x
14′ -0″
13′ -0″ x
14′ -8″
13′ -0″ x
14′ -9 3/4
4′ -6″ F 10′ -0″ x
13′ -7″
10′ -0″ x
13′ -4 1/2
10′ -0″ x
8′ -0″
DWG File PDF File
 10000 10′ -4″ x
14′ -0″
13′ -0″ x
14′ -10″
13′ -0″ x
15′ -1 1/2
4′ -6″ F/R 10′ -0″ x
13′ -6″
10′ -0″ x
13′ -1″
10′ -0″ x
8′ -0″
DWG File PDF File
 12000 12′ -4″ x
12′ -0″
15′ -8″ x
12′ -8″
15′ -8″ x
12′ -9 3/4
4′ -6″ F 12′ -0″ x
11′ -7″
12′ -0″ x
11′ -4 1/2
12′ -0″ x
8′ -0″
DWG File PDF File
 12000 12′ -4″ x
12′ -0″
15′ -8″ x
12′ -10″
15′ -8″ x
13′ -1 1/2
4′ -6″ F/R 12′ -0″ x
11′ -6″
12′ -0″ x
11′ -1″
12′ -0″ x
8′ -0″
DWG File PDF File
 15000 12′ -4″ x
16′ -0″
16′ -0″ x
16′ -8″
16′ -0″ x
16′ -9 3/4
5′ -0″ F 12′ -0″ x
15′ -7″
12′ -0″ x
15′ -4 1/2
12′ -0″ x
8′ -0″
DWG File PDF File
 15000  12′ -4″ x
16′ -0″
16′ -0″ x
16′ -10″
16′ -0″ x
17′ -1 1/2
5′ -0″ F/R 12′ -0″ x
15′ -6″
12′ -0″ x
15′ -1″
12′ -0″ x
8′ -0″
DWG File PDF File
 20000 12′ -4″ x
20′ -0″
16′ -0″ x
20′ -8″
16′ -0″ x
20′ -9 3/4
5′ -0″ F 12′ -0″ x
19′ -7″
12′ -0″ x
19′ -4 1/2
12′ -0″ x
8′ -0″
DWG File PDF File
 20000 12′ -4″ x
20′ -0″
16′ -0″ x
20′ -10″
16′ -0″ x
21′ -1 1/2
5′ -0″ F/R 12′ -0″ x
19′ -6″
12′ -0″ x
19′ -1″
12′ -0″ x
8′ -0″
DWG File PDF File
 25000 14′ -4″ x
20′ -0″
18′ -0″ x
20′ -8″
18′ -0″ x
20′ -9 3/4
5′ -6″ F 14′ -0″ x
19′ -7″
14′ -0″ x
19′ -4 1/2
14′ -0″ x
8′ -0″
DWG File PDF File
 25000 14′ -4″ x
20′ -0″
18′ -0″ x
20′ -10″
18′ -0″ x
21′ -1 1/2
5′ -6″ F/R 14′ -0″ x
19′ -6″
14′ -0″ x
19′ -1″
14′ -0″ x
8′ -0″
DWG File PDF File

 Automobile Lifts
 Cap.    Platform
Platform Width x Platform Depth
Hoistway
With
Power
Regular
Doors
Hoistway Width x Hoistway Depth
Hoistway
With
Power
Pass
Doors
Hoistway Width x Hoistway Depth
Pit
Depth
Pit Depth
Front
(F)
Rear
(R)
Clear
Inside
With
Single
Section
Clear
Inside
With
Two
Section
Door
Width
and
Height
Clear Door Width x Clear Door Height
 8000 9′ -4″ x
21′ -8″
12′ -0″ x
22′ -4″
12′ -0″ x
22′ -5 3/4
4′ -6″ F 9′ -0″ x
21′-3″
9′ -0″ x
21′ -0 1/2
9′ -0″
 8000 9′ -4″ x
21′ -8″
12′ -0″ x
22′ -6″
12′ -0″ x
22′ -9 1/2
4′ -6″ F/R 9′ -0″ x
21′-2″
9′ -0″ x
20′ -9″
9′ -0″


Code year adoptions and local code variations may affect the hoistway size. Verify all dimensions with MEI prior to construction.

This design utilizes wire ropes in conjunction with two hydraulic jacks to lift the car at a 1:2 ratio. For every foot that the jacks rise, the car rises two feet. The use of two jacks, one on each side of the car, provides maximum structural stability.

  • No jack hole is required and with that there is no risk of oil contamination in the ground.
  • Accommodates front and rear opening in any configuration.
  • Available for both low and high capacity cars.
  • No extensive pit or overhead is required.
  • Large platform designs and high capacity projects can be accommodated.

Headquarters

19336 607th Avenue
Mankato, MN 56001

  • Manufacturing Plant
  • Field Ops

Field Offices

MEI-Badger Elevator
MEI-Duluth Office
MEI-Kansas City Office
MEI-Northeast Office
MEI-St. Paul Office
MEI-Michigan Elevator
MEI-Springfield, MO
MEI-Wichita, KS
MEI-Colorado Office

Follow MEI